Premier Security Ballistic & Blast Ltd

Data Centre Security Solutions UK

Data Centre Security: Specifying the Building Envelope for UK Critical National Infrastructure

Premier Security Ballistic & Blast Ltd manufactures independently certified doors, windows, glazing, curtain walling and hostile vehicle mitigation systems for UK data centres. Our combined-rating product range protects against forced entry, ballistic attack, blast and fire, often within a single certified assembly, making us a specialist partner for the hyperscale operators, colocation providers and design teams building the country's newly designated Critical National Infrastructure.

LPS 1175 for Data Centres

B3 to E10 doors, windows & glazing

HVM for Data Centres

PAS 68 & IWA 14-1 bollards, gates & curtain walling

Ballistic, Blast & Fire

Combined-rating doors, glazing & curtain walling

Standards Reference

NPSA, EN 50600, ISO 27001 & Uptime Tier IV

Why Data Centre Physical Security Matters Now

On 12 September 2024, the UK government formally designated data centres as Critical National Infrastructure (CNI), placing them in the same protected category as energy, water and emergency services. It was the first new CNI designation since space and defence in 2015, and it changes the conversation around physical security for every operator, designer and main contractor working on a UK data centre project.

The designation arrived alongside a wave of investment that has fundamentally reshaped the sector. Blackstone has committed £10 billion to a hyperscale AI campus at Blyth, AWS has pledged £8 billion through 2028, Microsoft £2.5 billion, Google £1 billion at Waltham Cross and DC01UK £3.75 billion in Hertfordshire. The UK now hosts more than 500 data centres, with around 80 percent of national stock concentrated in the London region and clusters expanding across Slough, Hertfordshire, Manchester, Cardiff, Edinburgh and Cambois.

This combination of CNI status, hyperscale AI infrastructure and an active threat landscape (from organised intrusion and ram-raid through to ideologically motivated activism and hostile reconnaissance) has made data centre physical security a board-level concern. Specifiers are now expected to demonstrate layered protection that meets NPSA guidance, Uptime Institute Tier III to Tier IV expectations, ISO 27001 Annex A.11 physical controls and EN 50600-2-5, all backed by independently certified products with traceable documentation under the Building Safety Act's Golden Thread.

Critical National Infrastructure status: CNI designation does not yet impose new statutory product requirements, but the planned Cyber Security and Resilience Bill is expected to formalise expectations for data centres above 1MW per site or 10MW aggregate. Specifying independently certified physical security products now protects projects against future tightening.

The UK Data Centre Threat Model

UK data centre security planning works to NPSA's "Deter, Detect, Delay" framework, supported by the "Barriers, Access control, Detect" model for the building envelope. Premier's products sit firmly in the Barriers and Delay layers, where independently certified resistance to forced entry, ballistic attack, blast and fire is what slows or stops an adversary long enough for detection and response to take effect.

A modern UK data centre brief typically addresses five overlapping threat categories:

Forced entry and intruder attack

Theft of high-value hardware, sabotage, insider-assisted breach and opportunistic intrusion. Mitigated by LPS 1175 rated doors, windows, glazing, louvres, security curtain walling, gates and grilles, with ratings typically running from B3 (SR2) at the perimeter line through to E10 (SR5) at sensitive internal compartments.

Vehicle-borne attack

Vehicle-as-a-weapon, ram-raid and vehicle-borne improvised explosive device (VBIED) scenarios. Mitigated by PAS 68 and IWA 14-1 rated hostile vehicle mitigation including HVM bollards, sliding security gates, road blockers, PIPS HVM and crash-rated curtain walling at building entries and vehicle interfaces.

Ballistic attack

Targeted attack on personnel, control rooms, meet-me rooms and high-value plant. Mitigated by EN 1522 and EN 1523 rated ballistic doors and windows from FB1 to FB7, supported by EN 1063 BR1 to BR7 ballistic glazing in transaction screens, vision panels and full glazed assemblies.

Blast and explosion

Improvised devices, accidental industrial events (notably lithium-ion battery thermal runaway in UPS and BESS rooms) and proximity terror scenarios. Mitigated by EN 13123-2 and EN 13124-2 rated blast doors, EN 13541 ER1 to ER4 blast glazing and ISO 16933 air-blast classified assemblies, often integrated with the building envelope as blast-rated curtain walling.

Fire and dual-threat scenarios

Battery rooms, UPS and generator halls combine high fire load with security risk. Mitigated by EN 1634-1, EN 16034 and BS 476 Part 22 rated fire doors, with the strongest specifications coming from dual-certified assemblies that hold LPS 1175 forced entry resistance alongside EI 60 to EI 240 fire integrity and insulation ratings in a single tested product.

Standards That Shape Data Centre Specification

Premier products are tested and certified to the standards UK data centre specifiers reference in their NBS specifications and tender packs. The eight standards below cover the majority of building envelope and perimeter requirements on a typical hyperscale or colocation project.

LPS 1175 Issue 8

The dominant UK forced entry resistance standard, published by the BRE's Loss Prevention Certification Board. Replaces the SR1 to SR8 scale with a letter-and-number system (A1 to H20) describing tool category and attack duration. Premier holds ratings up to E10 (SR5) across doors, windows, glazing, louvres and curtain walling.

NPSA & NCSC Guidance

The National Protective Security Authority's data centre security guidance is the de facto UK reference for layered physical security. Premier's product range maps directly to NPSA's barriers and delay recommendations across perimeter, building envelope and internal compartments.

EN 1522 / 1523 & EN 1063

European ballistic standards covering doors, windows and shutters (EN 1522/1523) and security glazing (EN 1063). Premier's ballistic products are independently certified from FB1 to FB7 and BR1 to BR7, including the AK47 open class threat profile.

EN 13123-2 & EN 13541

Explosion resistance standards for doors, windows, shutters (EN 13123-2 / EN 13124-2) and glazing (EN 13541). Premier's blast products are certified up to EXV10 and ER4, with selected curtain walling assemblies tested to ISO 16933 arena air-blast classifications.

PAS 68 & IWA 14-1

The two principal vehicle security barrier standards. PAS 68 is the original UK specification; IWA 14-1 is the ISO equivalent now used internationally. Premier's HVM bollards, sliding gates and HVM curtain walling are tested to both, supporting NPSA's Vehicle Attack Delay Standard.

EN 50600-2-5 & ISO 27001

EN 50600-2-5 is the European technical standard for data centre security systems, used on new builds across the EU and increasingly in the UK. ISO 27001 Annex A.11 covers physical and environmental security controls, the compliance backbone for most colocation operators.

Uptime Institute Tier III & IV

Operational topology standards that drive door, glazing and access portal specification. Tier IV almost always requires anti-tailgating security portals, layered biometric access and high-rated forced entry resistance on data hall and MMR boundaries.

Secured by Design

The UK Police Preferred Specification scheme. Premier is a Secured by Design member, providing planning-application support and police-recognised specification credibility on UK data centre developments.

Premier Products Mapped to Data Centre Zones

The table below maps Premier's product range to the zones of a typical UK hyperscale or colocation data centre. Most projects layer two or more threat ratings across the same envelope, which is where Premier's combined-rating manufacturing comes into its own.

Data Centre Zone Primary Threats Recommended Premier Products
Site perimeter Vehicle attack, forced entry, hostile reconnaissance HVM bollards (PAS 68), sliding security gates, PIPS HVM, HVM curtain walling, LPS 1175 rated pedestrian gates
Vehicle entry & loading bay Ram-raid, VBIED, theft of hardware in transit Crash-rated sliding gates, HVM bollards, blast-rated industrial doors, LPS 1175 SR3 to SR4 personnel doors
Reception & visitor screening Forced entry, ballistic, tailgating LPS 1175 SR3 to SR5 glazed doors, ballistic transaction screens (FB4 to FB6), anti-tailgating security portals, mantraps
Control room & MMR Ballistic, forced entry, fire Ballistic doors (EN 1522 FB4 to FB6), ballistic glazing (EN 1063 BR4 to BR6), dual-certified ballistic and fire-rated doors
Data halls Forced entry, fire, insider threat LPS 1175 SR3 to SR5 swing and sliding doors, dual-certified LPS 1175 plus fire doors (EI 60 to EI 120), retractable security grilles for internal zoning
Plant rooms & mechanical spaces Forced entry, fire, acoustic, blast (BESS) LPS 1175 louvre doors, fire-rated louvre doors (E60 and E90), blast-rated ventilation louvres, dual-certified fire and security doors
UPS & battery rooms Lithium-ion thermal runaway, blast, fire Blast-rated doors (EN 13123-2), fire-rated doors EI 120 to EI 240, blast-rated louvres, dual-certified blast and fire assemblies
Generator halls Acoustic, fire, blast, forced entry Acoustic-rated fire doors, blast-rated louvre doors, LPS 1175 SR3 industrial doors
TEMPEST & classified compute EMI/RFI emanation, ballistic, forced entry EMI/RFI shielded ballistic doors, RF-shielded security hatches, integrated shielded wall assemblies

Combined Ballistic, Blast, Fire and Forced Entry Protection

Most UK manufacturers specialise in one threat category. Premier is one of the very few that holds independent third-party certification across all four. Our flagship HVM glass curtain walling system, the first glass curtain wall to pass HVM crash testing, combines FB7 ballistic resistance, EXV10 blast resistance, LPS 1175 E10 forced entry resistance and a U-value of 0.5 in a single assembly. The same combined-certification approach runs through our doorsets and glazing.

Why combined certification matters on a data centre project: A single dual-certified or quad-certified product gives the specifier one tested assembly, one certificate chain and one supplier accountable for performance against multiple threats. This streamlines NBS specification, reduces design coordination risk, and simplifies the Golden Thread documentation required under the Building Safety Act.

Combined-rating products are typically specified at:

  • Control rooms and meet-me rooms where ballistic and fire ratings are both required
  • UPS and battery rooms where blast and fire ratings must be carried by the same door
  • External envelope zones where ballistic, blast and LPS 1175 resistance are all in scope
  • High-threat reception and visitor screening areas
  • Government, defence-adjacent and intelligence-related compute environments

Explore Our Data Centre Security Solutions

Each pillar below covers a specific threat category in depth, with product ratings, application guidance and certification detail.

LPS 1175 for Data Centres

B3 to E10 doors, windows & glazing

HVM for Data Centres

PAS 68 & IWA 14-1 bollards, gates & curtain walling

Ballistic, Blast & Fire

Combined-rating doors, glazing & curtain walling

Standards Reference

NPSA, EN 50600, ISO 27001 & Uptime Tier IV

Who We Work With on UK Data Centre Projects

Premier supplies and installs across the full UK data centre supply chain, from architectural design teams briefing a new hyperscale campus through to facilities managers retrofitting LPS 1175 doors on an existing colocation floor.

  • Hyperscale operators
  • Colocation providers
  • Cloud & AI infrastructure
  • Edge data centres
  • Telecoms data centres
  • Financial services compute
  • Government & defence-adjacent
  • Specifier architects
  • M&E consultants
  • Main contractors
  • Security consultants
  • Facilities & FM teams

Download our UK Data Centre Security Specifier's Checklist

A practical eight-page reference for architects, M&E consultants and security designers working on UK data centre projects. Covers NPSA-aligned threat zoning, LPS 1175 rating selection, HVM specification and the standards Premier products meet at each layer of the building envelope.

Get the Checklist

Frequently Asked Questions

What physical security standards apply to UK data centres?

UK data centre physical security is shaped by NPSA and NCSC guidance, supported by LPS 1175 Issue 8 for forced entry resistance, EN 1522/1523 and EN 1063 for ballistic protection, EN 13123-2 and EN 13541 for blast resistance, PAS 68 and IWA 14-1 for hostile vehicle mitigation, EN 50600-2-5 for data centre security systems and ISO 27001 Annex A.11 for physical controls. Uptime Institute Tier III and Tier IV topology requirements drive door and portal specification on the majority of new builds.

What does Critical National Infrastructure status mean for data centre specification?

The September 2024 CNI designation places UK data centres under stronger government coordination on security and resilience, and is expected to be reinforced by the forthcoming Cyber Security and Resilience Bill. For specifiers, the practical effect is rising scrutiny of physical security layers, a stronger expectation of independently certified products at the building envelope and perimeter line, and tighter documentation requirements under the Building Safety Act's Golden Thread.

What LPS 1175 rating should I specify for a data hall door?

Specifications vary by operator, but the working consensus on UK data centre projects is B3 (SR2) as a minimum at the outer perimeter line, C5 (SR3) to D10 (SR4) at the building envelope and across data hall boundaries, and D10 to E10 (SR4 to SR5) at high-sensitivity zones such as MMR, control rooms and government-adjacent compute. Premier supplies independently certified doorsets, glazing and curtain walling across the full B3 to E10 range.

PAS 68 or IWA 14-1 for HVM at a data centre?

Both standards are recognised by NPSA and most UK data centre operators. PAS 68 is the original UK specification and remains the most commonly cited on UK projects. IWA 14-1 is the ISO-aligned successor and is preferred where international design teams or multinational operators are involved. Premier's HVM bollards, sliding gates and HVM curtain walling are independently certified to both, so the choice can be made on the basis of operator preference rather than product availability.

Can ballistic, blast and fire ratings be combined in one product?

Yes, and on UK data centre projects this is increasingly the default specification in high-threat zones. Premier manufactures dual-certified and quad-certified assemblies including doorsets, glazed screens and curtain walling that hold simultaneous ratings for ballistic resistance (up to FB7), blast resistance (up to EXV10), LPS 1175 forced entry resistance (up to E10) and fire integrity (EI 60 to EI 240). Combining ratings into a single tested product simplifies specification, reduces design risk and gives a single point of accountability for performance.

Is Premier a Secured by Design and LPCB certified manufacturer?

Yes. Premier is a Secured by Design member and our LPS 1175 rated products are LPCB approved and Red Book listed. Our ballistic and blast products are independently tested by BRE and other accredited laboratories. We hold ISO 9001 certification and supply on Constructionline Gold approved projects across the UK.

Speak to our data centre team

Whether you are at RIBA Stage 2 briefing a new hyperscale campus, finalising NBS specifications for a colocation fit-out, or retrofitting LPS 1175 doors on an existing site, Premier's data centre specification team can help you map products to your threat profile and Tier requirement. Get in touch for a no-obligation specification review.

Request a Specification Review
Premier Security Ballistic & Blast Ltd Logo

Security Ballistic & Blast Ltd