FB2 to FB7 rated assemblies with BR rated glazing, independently tested and available dual certified with blast, fire and LPS 1175.
Explore ballistic protection →EXV rated doors, windows, glazing and curtain walling engineered for vehicle borne and hand carried explosive threats.
Explore blast protection →30 to 120 minute EI and E rated door sets, including the UK's leading dual certified fire and security assemblies.
Explore fire protection →Certified intruder resistant doors, windows, glazing and perimeter systems with Secured by Design status.
Explore LPS 1175 ratings →Hostile vehicle mitigation (HVM) is a core layer of physical security for any UK data centre carrying Critical National Infrastructure status. Premier Security Ballistic & Blast Ltd designs, manufactures and installs ISO 22343-1:2023 rated HVM bollards, sliding security gates, PIPS HVM and crash-rated curtain walling, including the first glass curtain wall system to pass HVM crash testing, protecting the perimeter line, vehicle interfaces and building facade against vehicle-as-a-weapon and vehicle-borne improvised explosive device (VBIED) attack.
A vehicle is the most accessible high-impact weapon available to an attacker. A heavy goods vehicle travelling at speed can carry a significant explosive payload to within metres of a target, or be used directly as a battering ram to breach a perimeter and gain access to high-value compute hardware. For data centres, where a single facility can underpin national banking, government, healthcare and cloud services, the consequence of a successful vehicle attack extends far beyond the site itself.
The September 2024 designation of UK data centres as Critical National Infrastructure has sharpened expectations around perimeter protection. NPSA guidance now expects operators of high-criticality sites to demonstrate a proportionate, layered HVM scheme derived from a Vehicle Dynamics Assessment and a documented Operational Requirement, with vehicle security barriers tested and rated to the current internationally recognised standard. Increasingly, planning authorities and insurers also expect to see crash-rated mitigation at the perimeter and vehicle approaches of new hyperscale and colocation developments.
HVM in the NPSA layered model: Hostile vehicle mitigation sits in the outermost layers of NPSA's "Deter, Detect, Delay" model. Effective HVM keeps a hostile vehicle at a safe standoff distance, denies vehicle-borne access to the building, and channels legitimate traffic through controlled, rated entry points such as sliding gates and rising bollards.
HVM products are rated by their ability to stop a defined vehicle travelling at a defined speed. ISO 22343-1:2023 is the current international standard governing the performance testing and rating of vehicle security barriers (VSBs), and is the standard recognised by the UK's National Protective Security Authority for HVM specification. Premier's HVM products are independently impact-tested and certified to ISO 22343-1, giving specifiers a single, globally consistent rating to work from across UK and international data centre projects.
An ISO 22343-1 classification looks complex but decodes simply. Take Premier's own HVM curtain wall rating, V/7200[N2A]/64/90:0.0/0.0:
| Element | Example Value | Meaning |
|---|---|---|
| Test type | V | Vehicle impact test |
| Vehicle mass | 7200 | Test vehicle weighed 7,200 kg |
| Vehicle category | [N2A] | Medium goods vehicle category |
| Test speed | 64 | Impact speed of 64 km/h (around 40 mph) |
| Impact angle | 90 | Vehicle struck the barrier head-on at 90 degrees |
| Penetration | 0.0 | Vehicle penetration distance beyond the barrier line, in metres |
| Debris distance | 0.0 | Distance travelled by dislodged debris beyond the barrier line, in metres |
The lower the penetration and debris distance figures, the better the barrier performed. For data centre applications, the specifier selects the vehicle category, mass and speed that reflect the credible threat at each entry point, then chooses a barrier whose tested penetration keeps the building outside the standoff distance.
| Category | Vehicle Type | Typical Test Mass |
|---|---|---|
| M1 | Car | 1,500 kg |
| N1 | Small van / light goods | up to 3,500 kg |
| N2A | Medium goods vehicle | 3,500 to 7,500 kg |
| N3 | Rigid heavy goods vehicle | 7,500 kg and above |
Specifier note: Always compare the underlying test data behind an ISO 22343-1 rating (vehicle category, mass, speed, impact angle, penetration and debris distance) rather than the headline label alone, as this gives the clearest picture of how a barrier will perform against your assessed threat. Premier supplies full test certificates for every HVM product.
An effective HVM scheme is not a catalogue of products, it is a designed response to an assessed threat. Premier works with security consultants and design teams to develop HVM schemes that satisfy NPSA expectations while keeping the site operational and accessible to legitimate traffic.
HVM and the building facade: Where standoff distance is constrained by a tight urban site (common around London-edge and M4 corridor data centres), the building envelope itself can be hardened. Premier's HVM crash-tested glass curtain wall lets architects achieve a rated facade where a conventional standoff perimeter is not achievable, integrating ballistic and blast resistance into the same assembly.
Premier manufactures and installs the full range of HVM products required across a data centre site, from the outer perimeter line through to the building facade. Every product is independently impact-tested and certified to ISO 22343-1:2023.
| Product | Application | Notes |
|---|---|---|
| HVM bollards | Perimeter line, building approaches, pedestrian zones | Static, removable and automatic rising options; ISO 22343-1 rated; foundation and shallow-mount versions available |
| Sliding security gates | Vehicle entrances, loading bay access | Crash-rated tracked and cantilever sliding gates combining HVM performance with LPS 1175 forced entry resistance |
| PIPS HVM | Perimeter intrusion and vehicle mitigation combined | Integrated perimeter solution merging hostile vehicle mitigation with intrusion protection along the site boundary |
| HVM curtain walling | Building facade where standoff is constrained | The first glass curtain wall to pass HVM crash testing; combined ballistic (FB7), blast (EXV10) and LPS 1175 (E10) ratings available |
| Road blockers & barriers | Controlled high-threat vehicle entry points | Rising road blockers and rated barriers for active control of vehicle access at gatehouses and screening areas |
Premier's ISO 22343-1 rated bollards provide a discreet but highly effective perimeter line for data centres. Static bollards protect fixed lines and building approaches, automatic rising bollards control vehicle entry points, and removable bollards allow occasional access for maintenance and deliveries. Shallow-mount foundation options suit sites with underground services or limited excavation depth.
For vehicle entrances and loading bays, Premier's crash-rated sliding gates combine HVM impact resistance with LPS 1175 forced entry resistance in a single product, controlling vehicle access without creating a weak point in the perimeter line. Tracked and cantilever configurations are available to suit ground conditions and opening widths.
Premier's HVM crash-tested glass curtain wall is the standout product for data centres on constrained sites. As the first glass curtain wall system to pass HVM crash testing, it allows a rated, glazed facade where conventional standoff cannot be achieved, and can be specified with combined ballistic, blast and LPS 1175 ratings to harden the entire building envelope in one assembly.
Includes HVM scheme guidance, ISO 22343-1 rating selection, standoff and Vehicle Dynamics Assessment basics, and how Premier's HVM products integrate with the wider building envelope.
Get the ChecklistHostile vehicle mitigation is the use of crash-rated barriers, bollards, gates and hardened building elements to stop a vehicle being used as a weapon, whether as a direct ram-raid or to deliver a vehicle-borne explosive payload. For data centres, HVM keeps hostile vehicles at a safe standoff distance and denies vehicle-borne access to high-value compute hardware.
ISO 22343-1:2023 is the current international standard for testing and rating vehicle security barriers, and is the standard recognised by NPSA for UK HVM specification. Premier's HVM products are independently tested and certified to ISO 22343-1, giving specifiers a single consistent rating across UK and international data centre projects.
The rating is derived from a Vehicle Dynamics Assessment, which models the credible vehicle category, mass and the maximum speed achievable at each approach, combined with the standoff distance the building facade requires. The selected barrier must have a tested penetration distance that keeps the impacting or detonating vehicle outside that standoff line. Premier can support this assessment with security consultants as part of a specification review.
An ISO 22343-1 rating sets out the test type, the vehicle mass and category, the impact speed and angle, and the resulting penetration and debris distance beyond the barrier line. Comparing the underlying test data, rather than the headline classification alone, gives the clearest picture of how a barrier will perform against an assessed threat. Premier provides full test certificates for every HVM product.
Yes. Where site constraints prevent a conventional standoff perimeter, the building envelope itself can be hardened. Premier's HVM crash-tested glass curtain wall, the first glass curtain wall to pass HVM crash testing, provides a rated glazed facade and can be specified with combined ballistic, blast and LPS 1175 forced entry ratings in the same assembly.
Yes. Premier's crash-rated sliding security gates combine ISO 22343-1 HVM performance with LPS 1175 forced entry resistance in a single product, so the vehicle entry point does not become a weak link in the perimeter line. This is a common requirement at data centre loading bays and main vehicle entrances.
Premier's team works with security consultants, architects and main contractors to develop ISO 22343-1 rated HVM schemes derived from your Operational Requirement and Vehicle Dynamics Assessment, integrated with the wider building envelope. Get in touch for a no-obligation specification review.
Request a Specification Review