FB2 to FB7 rated assemblies with BR rated glazing, independently tested and available dual certified with blast, fire and LPS 1175.
Explore ballistic protection →EXV rated doors, windows, glazing and curtain walling engineered for vehicle borne and hand carried explosive threats.
Explore blast protection →30 to 120 minute EI and E rated door sets, including the UK's leading dual certified fire and security assemblies.
Explore fire protection →Certified intruder resistant doors, windows, glazing and perimeter systems with Secured by Design status.
Explore LPS 1175 ratings →LPS 1175 E10, the Issue 8 rating commonly compared with SR5, certifies that a complete product has resisted a sophisticated, well-resourced attacker using high-end 36V cordless tools for at least ten minutes. It is widely specified for critical national infrastructure, government buildings, military sites and high-security embassies, and it sits at the top of Premier Security's certified range. Premier Security Ballistic & Blast Ltd manufactures E10 certified Ultimate High Security Curtain Walling 5 and Kraken 5 automatic sliding gates, both listed on LPCB Red Book Live.
LPS 1175 is the Loss Prevention Standard for intruder resistant building components, published by the Loss Prevention Certification Board (LPCB), part of BRE Global. Every Issue 8 rating has two parts: the letter sets the tools the attacker can use, and the number sets the minimum delay in minutes the product must achieve.
At E10, the test team attacks the locked product with Category E tools and must not create a 400 mm x 225 mm opening, the minimum size a person can climb through, within ten minutes of working time. Any part of the assembly can be targeted, including frames, glazing, infill panels, locks, fixings and the gate or facade structure itself.
Category E represents a sophisticated attacker with the most powerful battery tools commercially available, prepared to make noise and work through a sustained attack. The kit includes everything in Categories A to D plus:
The step from D10 to E10 keeps the same ten-minute delay but raises the power of the cutting tools. Higher-voltage saws and grinders cut faster and deeper, so an E10 product has to resist a much more aggressive cutting attack for the full ten minutes.
| Issue 8 | Issue 7 | Tool category | Minimum delay | Typical use |
|---|---|---|---|---|
| D10 | SR4 | D: 18V cordless disc grinders, reciprocating saws, sledgehammer | 10 minutes | High-value commercial, industrial, utilities, data centres |
| E10 | SR5 | E: 36V cordless tools, circular saws, high-power reciprocating saws | 10 minutes | Critical national infrastructure, government, military, embassies |
| F10 | SR6 | F: mains-powered saws and grinders (2000W+), oxyacetylene cutting | 10 minutes | High-security government, specialist installations |
LPS 1175 Issue 8 came into effect in 2019 and was the most substantial revision of the standard to date. It replaced the single SR1 to SR8 scale with a tool category letter (A to H) followed by a minimum delay in minutes (1, 3, 5, 10, 15 or 20). E10 is the Issue 8 classification commonly compared with the old SR5.
Under Issue 7, the tool set behind SR5 was an enhanced Category D kit, often written as D+. Issue 8 made it a category in its own right, Category E, which is why the SR5 equivalent carries a new letter rather than a longer delay. All of Premier Security's E10 products are certified under Issue 8, so their certificates show E10 and the products can be described as E10 (SR5).
Check the letter and the number: Issue 8 allows Category E tools to be tested to different delays, so E5 and E15 also exist alongside E10. An E5 product resists for half the time of an E10 product. Always check both parts of the rating on the certificate.
Specifier note: where a specification calls for LPS 1175 SR5, Issue 8 E10 is the current classification for that threat level. If the wording insists on Issue 7 specifically, confirm with the specifier that an E10 product is acceptable before ordering.
Premier Security holds LPCB certification for the following products at E10. Openings outside the certified scope are not covered by the rating, so our technical team will confirm the certified configuration for every opening.
| Product | LPCB ref | Configurations | Certified structural opening |
|---|---|---|---|
| Ultimate High Security Curtain Walling 5 | 1097w/01 | Glazed curtain walling, achieving its rating from either the external or the internal face | Confirmed per project by our technical team against the certificate |
Ultimate High Security Curtain Walling 5 is the top of a family that runs from C5 (SR3) through D10 (SR4) to E10 (SR5). Panels are glazed only, and structural design of the facade sits outside LPS 1175. It is also the most comprehensively tested product in Premier Security's range, with ballistic, blast, vehicle impact and weather performance evidence alongside its E10 certificate (see below). See our security curtain walling.
| Product | LPCB ref | Configurations | Certified size |
|---|---|---|---|
| Kraken 5 cantilever sliding gate | 1097x/01 | Automatic operation only | 0.5 m to 6.0 m high x 1.0 m to 12.0 m wide; minimum free-standing height 2.8 m |
Kraken 5 is certified for automatic operation only, with a Surelock McGill electromechanical lock or IGEM maglock and BFT or AYROS gate motors. Gates below 2.8 m high must be installed within a four-sided structural opening, with a maximum ground gap of 90 mm, flat level ground and foundations offering equivalent attack resistance. Any access control must offer at least 100,000 effective codes, a higher threshold than the 30,000 required for the C5 and D10 Kraken gates. See our vehicle access sliding gates and security gates.
Sites that need E10 often face more than one threat. LPS 1175 covers forced entry only, so ballistic, blast and vehicle impact performance each need their own test evidence. The Ultimate High Security Curtain Walling family holds the following, each applying to the configuration tested:
| Discipline | Standard | Result | Basis |
|---|---|---|---|
| Forced entry | LPS 1175 Issue 8 | E10 (SR5), certificate 1097w | LPCB certification |
| Vehicle impact | ISO 22343-1:2023 | V/7200[N2A]/64/90:0.0/0.0, a 7.5 tonne truck at approximately 64 km/h with zero penetration | UKAS accredited test, HORIBA MIRA (laboratory 1105) |
| Ballistic | EN 1522/1523 methodology | FB7, NS (no splinters) | Tested to methodology, not UKAS accredited |
| Blast | ISO 16933 | EXV25 to EXV10 | Blast test evidence |
| Weather | BS EN 12153, 12155 and 12179 | Air permeability AE1200, watertightness RE2000, wind load criteria met at +2400 Pa and -2200 Pa | BRE test report |
The weather results come from a BRE test report rather than a certification. The family also achieves U-values as low as 0.5. For the full detail, see our Ballistic Resistance and Blast Resistance guides and the Hostile Vehicle Mitigation range.
E10 suits sites where the credible threat is a sophisticated, well-resourced attacker, and where a breach would have serious consequences for national security, public safety or critical services. Typical applications include:
The right rating comes from a security risk assessment that weighs the asset value, the likely capability of an attacker and the time a response needs to arrive. In critical infrastructure and government contexts, that assessment is typically informed by NPSA (National Protective Security Authority) guidance. Our technical team can review the assessment and recommend a rating for each opening.
For data centre halls, utilities and high-value commercial sites where the threat is an experienced attacker with 18V power tools, D10 (SR4) is the common choice.
Where an assessment points to mains-powered tools or a multi-person attack, ratings such as F10 (SR6) apply, and layered protection becomes important. Each certified layer, such as an E10 perimeter gate and an E10 facade, keeps its own rating; ratings do not add together, but every layer adds delay and a chance to detect the attack.
E10 is the Issue 8 classification commonly compared with SR5: both describe a sophisticated attack held off for at least ten minutes. Under Issue 7 the SR5 tool set was an enhanced Category D kit, often written as D+, which Issue 8 turned into Category E. Premier Security's E10 products are certified under Issue 8 and are often described as E10 (SR5). If a specification insists on Issue 7 SR5, confirm with the specifier that an Issue 8 E10 product is acceptable.
The Category E tool set: everything in Categories A to D, including 18V cordless disc grinders and reciprocating saws, plus 36V cordless tools, 750W reciprocating saws and high-power circular saws. Testers attack the locked product and must not create a 400 mm x 225 mm opening within ten minutes of working time.
Both require a ten-minute delay, but E10 is tested with a more powerful tool set. D10 uses 18V cordless power tools, while E10 adds 36V tools, 750W reciprocating saws and high-power circular saws. E10 is the step up for sites facing a sophisticated, well-resourced attacker.
Ultimate High Security Curtain Walling 5 (certificate 1097w) and the Kraken 5 automatic cantilever sliding gate (certificate 1097x), both certified to LPS 1175 Issue 8 E10.
Yes. Ultimate High Security Curtain Walling 5 is LPCB certified to E10, and the curtain walling family has been crash tested by HORIBA MIRA, a UKAS accredited laboratory, to ISO 22343-1:2023, stopping a 7.5 tonne truck at approximately 64 km/h with zero penetration. Each result applies to the configuration tested, so our team will confirm the specification that covers both.
The Kraken 5 gate is certified for automatic operation only. Manual operation is certified on the Kraken 2, 3 and 4 gates, up to D10 (SR4), so a manual sliding gate at E10 is not part of Premier Security's certified range.
Issue 8 continues with longer delays at Category E, such as E15 and E20, and with more powerful tool sets: F10 (SR6) introduces mains-powered tools and oxyacetylene cutting, and G10 (SR7) and H20 (SR8) go further still. Products at these levels are specialist and rare, so verify any claim directly against LPCB Red Book Live.
Premier Security Ballistic & Blast Ltd designs and manufactures LPS 1175 E10 certified curtain walling and sliding gates in the UK, with full certificate references and test evidence for every submission.
Contact our technical team to confirm the certified configuration for your project, request certificate copies or arrange a specification consultation.