Skip to main content

Premier Security Ballistic & Blast Ltd

LPS 1175 C5 (SR3) Rating Explained

LPS 1175 C5 (SR3) Security Rating: Certified Curtain Walling, Doorsets and Gates

LPS 1175 C5, the Issue 8 rating commonly compared with SR3, certifies that a complete product has resisted a deliberate, planned attack with Category C tools, including an axe, crowbar and gas torch, for at least five minutes. It is a common step up from SR2 for commercial premises, schools, healthcare and retail. Premier Security Ballistic & Blast Ltd manufactures LPCB certified C5 curtain walling doorsets, screens and fixed windows, Ultimate High Security Curtain Walling and Kraken 3 sliding gates, all listed on LPCB Red Book Live.

Issue 8 ratingC5Tool category C, 5 minutes
Compared withSR3Issue 7 Security Rating 3
Tool categoryCDeliberate, planned attack
Minimum delay5 minProduct tested locked
Breach target400 x 225mm, a person-sized opening

What Does LPS 1175 C5 Mean?

LPS 1175 is the Loss Prevention Standard for intruder resistant building components, published by the Loss Prevention Certification Board (LPCB), part of BRE Global. Every Issue 8 rating has two parts: the letter sets the tools the attacker can use, and the number sets the minimum delay in minutes the product must achieve.

At C5, the test team attacks the locked product with Category C tools and must not create a 400 mm x 225 mm opening, the minimum size a person can climb through, within five minutes of working time. Any part of the assembly can be targeted, including the leaf, frame, glazing, infill panels, hinges, locks and fixings, so the whole product has to perform.

The Category C tool set

Category C assumes a planned attack by someone who has come prepared and is not concerned about noise. The kit includes everything in Categories A and B plus heavier leverage, impact and cutting tools:

  • Category A tools: screwdrivers, pliers, knives, small spanners, fishing line and traction screws
  • Added at Category B: bolt cutters, a claw hammer (up to 1 kg), a cordless drill, steel tube and shears
  • Added at Category C: an axe (up to 900 mm), cold chisels, brick bolsters, a crowbar, a lump hammer and a gas torch

That is a significant step up from SR2. An attacker with an axe, crowbar and lump hammer can apply far more force to frames, hinges and glazing than one with bolt cutters and a claw hammer, and the extra two minutes of delay give a response team more time to arrive.

LPS 1175 C5 compared with the ratings either side of it
Issue 8 Issue 7 Tool category Minimum delay Typical use
B3SR2B: bolt cutters, claw hammer, cordless drill3 minutesCommunal entrances, residential blocks, low-risk commercial
C5SR3C: axe, crowbar, lump hammer, gas torch5 minutesCommercial premises, schools, healthcare, retail
D10SR4D: 18V cordless disc grinders, reciprocating saws, sledgehammer10 minutesHigh-value commercial, industrial, utilities

C5 vs SR3: Issue 8 and Issue 7 Explained

LPS 1175 Issue 8 came into effect in 2019 and was the most substantial revision of the standard to date. It replaced the single SR1 to SR8 scale with a tool category letter (A to H) followed by a minimum delay in minutes (1, 3, 5, 10, 15 or 20). C5 is the Issue 8 classification commonly compared with the old SR3: a deliberate attack with Category C tools, held off for at least five minutes.

All of Premier Security's C5 products are certified under Issue 8, so their certificates show C5 and the products can be described as C5 (SR3) for comparison with older specifications.

Issue 7: Security Rating 3

  • Single number scale, SR1 to SR8
  • Deliberate attack, minimum 5 minutes
  • Still found in older specifications and on products whose Issue 7 certificates are maintained

Issue 8: C5

  • Tool category letter plus delay in minutes, A1 to H20
  • Category C attack, minimum 5 minutes
  • Often written as C5 (SR3) for comparison
  • Premier products: Jansen Façade C5 curtain walling range, Ultimate High Security Curtain Walling 3 and Kraken 3 sliding gates

Check the letter and the number: Issue 8 allows the same tool category to be tested to different delays, from C1 up to C20. A C3 product resists Category C tools for three minutes, not five, so it is not a C5 product even though the letter matches. Always check both parts of the rating on the certificate.

Specifier note: where a specification calls for LPS 1175 SR3, Issue 8 C5 is the current classification for that threat level. If the wording insists on Issue 7 specifically, confirm with the specifier that a C5 product is acceptable before ordering.

Premier Security's C5 Certified Products

Premier Security holds LPCB certification for the following products at C5. Sizes are the certified structural openings shown on each certificate. Openings outside these ranges are not covered by the rating, so our technical team will confirm the certified configuration for every opening.

Jansen Façade C5 curtain walling range

Issue 8 C5 (SR3) | Certs 1097g, 1097h, 1097i
ProductLPCB refConfigurationsCertified structural opening
Jansen Façade C5 Curtain Walling Doorset1097g/01Hinged single or double leaf, inward or outward opening, side panel optionsSingle leaf up to 6.07 m high x 1.7 m wide; double leaf up to 3.06 m x 3.28 m; unlimited width with side panels
Jansen Façade C5 Curtain Walling Screen1097h/01Modular security screen with glazed, opaque and/or louvre panels. Can incorporate the C5 doorsetFrom 0.485 m, with no maximum height or width on the certificate
Jansen Façade C5 Curtain Walling Fixed Window1097i/01Single fixed light with glazed and/or opaque panels, as a single infill or multiple infills in portcullis style framing0.485 m to 3.0 m high x 0.485 m to 3.0 m wide

The screen and fixed window are available in standard, thermally broken or fire rated profiles, with fire performance certified separately. Where the screen incorporates a doorset, the minimum opening is 0.57 m high x 0.82 m wide. The structural integrity of a screen sits outside the scope of LPS 1175 and must be designed for the building, and only the locking systems listed on certificate 1097g carry the rating. See our Jansen security doors and LPS 1175 security windows.

Ultimate High Security Curtain Walling 3

Issue 8 C5 (SR3) | Cert 1097u
ProductLPCB refConfigurationsCertified structural opening
Ultimate High Security Curtain Walling 31097u/01Glazed curtain walling, achieving its rating from either the external or the internal face0.646 m to 20.0 m high; width from 0.646 m with no upper limit

Ultimate High Security Curtain Walling is a separate, higher-specification system from the Jansen Façade range. The same family continues to D10 (SR4) and E10 (SR5), so a facade can be specified at C5 now with a clear upgrade path. Panels are glazed only, and structural design of the facade sits outside LPS 1175. See our security curtain walling.

Kraken 3 cantilever sliding gate

Issue 8 C5 (SR3) | Cert 1097q
ProductLPCB refConfigurationsCertified size
Kraken 3 cantilever sliding gate1097q/01Automatic or manual operation0.5 m to 6.0 m high x 3.0 m to 12.0 m wide; minimum free-standing height 2.4 m

Kraken 3 gates below 2.4 m high must be installed within a four-sided structural opening, with a maximum ground gap of 90 mm, flat level ground and foundations offering equivalent attack resistance. Automatic gates are certified with a Surelock McGill electromechanical lock or IGEM maglock, with BFT or AYROS gate motors; manual gates use a Surelock McGill lock with approved cylinders. Any access control must offer at least 30,000 effective codes. See our vehicle access sliding gates and security gates.

Where C5 Is Specified

C5 suits buildings where the credible threat is a planned attack with heavy hand tools, or where the assets inside justify more delay than SR2 provides. Typical openings and elevations include:

  • Glazed office entrances and reception screens
  • Schools and colleges
  • Healthcare buildings
  • Retail frontages and stockrooms
  • Light industrial premises
  • Commercial perimeters and service yards

The right rating comes from a security risk assessment that weighs the asset value, the likely capability of an attacker and the time a response needs to arrive. Our technical team can review the assessment and recommend a rating for each opening.

When SR2 / B3 is enough

For communal residential entrances and low-risk commercial openings where the threat is a determined opportunist, SR2 (B3) is the common choice.

Read the SR2 / B3 rating guide

When to step up to D10

If the threat includes power tools such as 18V disc grinders and reciprocating saws, or the asset value justifies a ten-minute delay, D10 (SR4) is more appropriate.

See our D10 (SR4) products

Specifying a C5 Product: Checklist

  • Confirm the certificate shows C5 under Issue 8 (both the letter and the number) and check the listing on Red Book Live
  • Check the opening size falls within the certified structural opening for the chosen configuration
  • Use only the locking systems listed on the certificate; other locks do not carry the rating
  • Confirm the glazing and infill panels are within the certified options for that product
  • Detail the fixings and substrate, as the frame to structure connection sits outside the certificate
  • For screens and curtain walling, design the structural performance separately, as it is outside the scope of LPS 1175
  • For Kraken 3 gates, allow for the 2.4 m minimum free-standing height and specify access control with at least 30,000 effective codes
  • Remember that resistance of access control systems to non-mechanical attack is outside the scope of LPS 1175

Frequently Asked Questions: LPS 1175 C5 and SR3

Is LPS 1175 C5 the same as SR3?

C5 is the Issue 8 classification commonly compared with SR3: both describe a deliberate attack with Category C tools held off for at least five minutes. Premier Security's C5 products are certified under Issue 8, so they carry C5 on their certificates and are often described as C5 (SR3). If a specification insists on Issue 7 SR3, confirm with the specifier that an Issue 8 C5 product is acceptable.

What tools are used to test a C5 product?

The Category C tool set: everything in Categories A and B (screwdrivers, pliers, knives, bolt cutters, a claw hammer, a cordless drill, steel tube and shears) plus an axe up to 900 mm, cold chisels, brick bolsters, a crowbar, a lump hammer and a gas torch. Testers attack the locked product and must not create a 400 mm x 225 mm opening within five minutes of working time.

Is C5 the same as C3 or C10?

No. Issue 8 uses the same Category C tools across several delay times. C3 means three minutes of resistance, C5 means five and C10 means ten. Always check both the letter and the number on the certificate, because a C3 product does not meet a C5 specification.

Which Premier Security products are certified to C5?

The Jansen Façade C5 Curtain Walling Doorset, Screen and Fixed Window (certificates 1097g, 1097h and 1097i), Ultimate High Security Curtain Walling 3 (1097u) and Kraken 3 cantilever sliding gates (1097q), all certified to LPS 1175 Issue 8 C5.

Can glazed curtain walling be certified to C5?

Yes. The Jansen Façade C5 range and Ultimate High Security Curtain Walling 3 are both certified to C5 with glazed panels, and Ultimate High Security Curtain Walling 3 is certified for openings up to 20 metres high with no width limit. The rating covers the assembly as tested; the structural design of the facade is a separate exercise.

Do C5 sliding gates need a minimum height?

Yes. A free-standing Kraken 3 gate must be at least 2.4 m high to carry its C5 rating. Lower gates carry the rating only when they are installed within a four-sided structural opening.

When should I specify D10 instead of C5?

When the risk assessment points to an experienced attacker with power tools, such as 18V disc grinders and reciprocating saws, or when the assets inside justify a ten-minute delay. Data centres, utilities, high-value commercial sites and embassies commonly specify D10 (SR4) or above.

Specify LPCB Certified C5 Products