LPS 1175 F10 (SR6) Rating Explained

LPS 1175 F10 (SR6) Security Rating Explained

LPS 1175 F10, the Issue 8 rating commonly compared with SR6, certifies that a complete product has resisted a professional, multi-person attack using mains-powered saws and grinders and oxyacetylene cutting equipment for at least ten minutes. It is a specialist rating for high-security government buildings, defence sites and the most critical areas of national infrastructure. This guide explains what F10 means, how it differs from E10 and SR6, and how to specify and verify an F10 product.

Issue 8 ratingF10Tool category F, 10 minutes
Compared withSR6Issue 7 Security Rating 6
Tool categoryFProfessional team, mains power
Minimum delay10 minProduct tested locked
Breach target400 x 225mm, a person-sized opening

What Does LPS 1175 F10 Mean?

LPS 1175 is the Loss Prevention Standard for intruder resistant building components, published by the Loss Prevention Certification Board (LPCB), part of BRE Global. Every Issue 8 rating has two parts: the letter sets the tools and the attack scenario, and the number sets the minimum delay in minutes the product must achieve.

At F10, the test team attacks the locked product with Category F tools and must not create a 400 mm x 225 mm opening, the minimum size a person can climb through, within ten minutes of working time. Any part of the assembly can be targeted, including frames, infill panels, glazing, locks, hinges and fixings.

The Category F tool set

Category F represents a professional, well-resourced team with access to mains power, prepared to make a great deal of noise. The kit includes everything in Categories A to E plus:

  • Categories A to E: hand tools, bolt cutters, an axe, a crowbar, a gas torch, sledgehammers, and 18V and 36V cordless saws and grinders
  • Added at Category F: mains-powered saws and grinders rated over 2000W, and an oxyacetylene cutting kit
  • Attack scenario: more than one attacker working on the product at the same time

Mains-powered tools do not run down like batteries, cut harder and faster than cordless equivalents, and oxyacetylene equipment can cut through thick steel. Combined with several attackers working together, that makes Category F a step change from E10 rather than an incremental one.

LPS 1175 F10 compared with the ratings either side of it
Issue 8 Issue 7 Tool category Minimum delay Typical use
E10SR5E: 36V cordless tools, circular saws, high-power reciprocating saws10 minutesCritical national infrastructure, government, military, embassies
F10SR6F: mains-powered saws and grinders (2000W+), oxyacetylene cutting, multiple attackers10 minutesHigh-security government, defence, specialist installations
G10SR7G: concrete chainsaws, hydraulic jacks, diamond-core drills10 minutesSpecialist high-security

F10 vs SR6: Issue 8 and Issue 7 Explained

LPS 1175 Issue 8 came into effect in 2019 and was the most substantial revision of the standard to date. It replaced the single SR1 to SR8 scale with a tool category letter (A to H) followed by a minimum delay in minutes (1, 3, 5, 10, 15 or 20). F10 is the Issue 8 classification commonly compared with the old SR6.

The letters can be confusing when moving between the two issues. Issue 7 used an enhanced Category D kit, written D+, for SR5. Issue 8 turned that kit into Category E, so every tool category above it moved up a letter: the Issue 7 tool set behind SR6, which was called Category E, corresponds to Issue 8 Category F. When comparing older documents with new ones, compare the rating, not just the letter.

Issue 7: Security Rating 6

  • Single number scale, SR1 to SR8
  • Issue 7 Category E tool set, minimum 10 minutes
  • Still found in older specifications and on products whose Issue 7 certificates are maintained

Issue 8: F10

  • Tool category letter plus delay in minutes, A1 to H20
  • Issue 8 Category F attack, minimum 10 minutes
  • Often written as F10 (SR6) for comparison

Check the letter and the number: Issue 8 allows Category F tools to be tested to different delays, so ratings such as F5 and F15 also exist. An F5 product resists for half the time of an F10 product. Always check both parts of the rating on the certificate.

Specifier note: where a specification calls for LPS 1175 SR6, Issue 8 F10 is the current classification for that threat level. If the wording insists on Issue 7 specifically, confirm with the specifier whether an F10 product is acceptable.

What F10 Means for Design and Installation

At F10, the product is only one part of the protection. A rating this high is usually specified as part of a wider security design, and several factors around the product decide whether the certified delay is achieved in practice:

  • Substrate and fixings: the wall, slab or foundation around the product needs equivalent attack resistance. A certified F10 door in a weaker wall simply moves the attack to the wall.
  • Access to mains power: Category F assumes the attacker can power heavy tools. Consider how external sockets and supplies near protected openings are controlled.
  • Detection and response: the delay only has value if an attack is detected early and a response arrives within it. Match the rating to the response time set in the threat assessment.
  • Layered protection: perimeter barriers, building envelope and internal secure rooms each add delay and a chance to detect the attack. Each layer keeps its own rating; ratings do not add together on a certificate.

Where F10 Is Specified

F10 is specified where the credible threat is a professional, well-resourced team and a breach would have severe consequences for national security, public safety or critical services. Typical applications include:

  • High-security government buildings
  • Critical national infrastructure control areas
  • Strongrooms and secure stores
  • High-risk embassies and diplomatic sites
  • Critical data and communications facilities

A rating at this level should always come from a formal threat assessment. In government and critical infrastructure contexts, that assessment is typically informed by NPSA (National Protective Security Authority) guidance, and it will set the attacker profile, the response time and therefore the rating required for each layer.

Specifying an F10 Product: Checklist

  • Confirm the product holds an LPCB certificate showing F10 under Issue 8 (both the letter and the number), and check the current listing on Red Book Live
  • Check that the certificate covers the exact configuration, size and opening direction being specified
  • Use only the locking systems listed on the certificate; other locks do not carry the rating
  • Design the surrounding wall, slab or foundation to match the attack resistance of the product
  • Detail fixings and the connection to the structure, which sit outside the certificate
  • Align the delay with the detection and response plan in the threat assessment
  • Plan an uninterrupted power supply for powered locking and access systems if the rating must hold during a mains failure
  • Remember that resistance of access control systems to non-mechanical attack is outside the scope of LPS 1175

Frequently Asked Questions: LPS 1175 F10 and SR6

Is LPS 1175 F10 the same as SR6?

F10 is the Issue 8 classification commonly compared with SR6: both describe a professional attack held off for at least ten minutes. Because Issue 8 turned the old D+ tool kit into Category E, the Issue 7 tool set behind SR6, called Category E, corresponds to Issue 8 Category F. A product holds whichever rating is on its LPCB certificate.

What tools are used to test an F10 product?

The Category F tool set: everything in Categories A to E, including 18V and 36V cordless power tools, plus mains-powered saws and grinders rated over 2000W and an oxyacetylene cutting kit. Category F also assumes more than one attacker. Testers attack the locked product and must not create a 400 mm x 225 mm opening within ten minutes of working time.

What is the difference between F10 and E10?

Both require a ten-minute delay, but F10 adds mains-powered tools over 2000W, oxyacetylene cutting and multiple attackers. E10 is limited to battery tools, so F10 represents a far more capable and better-resourced attack.

Is F10 the same as F5 or F15?

No. They use the same Category F tools but different delays: F5 requires five minutes of resistance, F10 ten and F15 fifteen. A lower delay does not meet a higher specification, so always check both the letter and the number on the certificate.

Which buildings need F10?

F10 is a specialist rating for high-security government buildings, defence sites, critical infrastructure control areas and similar sites where a professional team with mains-powered tools is a credible threat. The requirement should come from a formal threat assessment, typically informed by NPSA guidance.

How do I verify an F10 product?

Ask for the LPCB certificate and check the product's current listing on Red Book Live. Confirm the issue of the standard, the full rating (letter and number), the certified sizes and configurations, and the locking systems covered. A product described as F10 without an LPCB listing cannot be relied on in a formal specification.

Is F10 the highest LPS 1175 rating?

No. Issue 8 continues with longer delays at Category F, such as F15 and F20, and with Category G and H tool sets: G10 (SR7) adds concrete chainsaws, hydraulic jacks and diamond-core drills, and H20 (SR8) uses the most powerful tools short of explosives. Products at these levels are rare, so verify any claim directly against Red Book Live.

Get Specialist Advice on High-Security Specifications

Premier Security Ballistic & Blast Ltd works with security consultants, architects and specifiers on high-threat projects across government, defence and critical infrastructure.

Contact our technical team to talk through your threat assessment and the protection it calls for.

Get in Touch with Our Team

Related Premier Security Resources

Premier Security Ballistic & Blast Ltd Logo

Security Ballistic & Blast Ltd