Premier Security Ballistic & Blast Ltd
FB2 to FB7 rated assemblies with BR rated glazing, independently tested and available dual certified with blast, fire and LPS 1175.
Explore ballistic protection →EXV rated doors, windows, glazing and curtain walling engineered for vehicle borne and hand carried explosive threats.
Explore blast protection →30 to 120 minute EI and E rated door sets, including the UK's leading dual certified fire and security assemblies.
Explore fire protection →Certified intruder resistant doors, windows, glazing and perimeter systems with Secured by Design status.
Explore LPS 1175 ratings →LPS 1175 G10, the Issue 8 rating commonly compared with SR7, certifies that a complete product has resisted an attack with heavy construction and demolition equipment, including concrete chainsaws, hydraulic jacks and diamond-core drills, for at least ten minutes. It is one of the highest ratings in the standard, specified for vaults, strongrooms and the most sensitive areas of government, defence and critical infrastructure sites. This guide explains what G10 means, how it differs from F10 and SR7, and how to specify and verify a G10 product.
LPS 1175 is the Loss Prevention Standard for intruder resistant building components, published by the Loss Prevention Certification Board (LPCB), part of BRE Global. Every Issue 8 rating has two parts: the letter sets the tools and the attack scenario, and the number sets the minimum delay in minutes the product must achieve.
At G10, the test team attacks the locked product with Category G tools and must not create a 400 mm x 225 mm opening, the minimum size a person can climb through, within ten minutes of working time. Any part of the assembly can be targeted, including frames, infill panels, locks, hinges and fixings.
Category G represents an extreme threat: a well-equipped professional attack using construction-grade equipment against the product itself. The kit includes everything in Categories A to F plus:
These are tools for cutting, spreading and breaking concrete and heavy steel. Hydraulic jacks can force frames apart, diamond-core drills bore through solid sections, and concrete chainsaws cut through materials that defeat lighter tools. At this level the attack is as much about demolition as forced entry.
| Issue 8 | Issue 7 | Tool category | Minimum delay | Typical use |
|---|---|---|---|---|
| F10 | SR6 | F: mains-powered saws and grinders (2000W+), oxyacetylene cutting, multiple attackers | 10 minutes | High-security government, defence, specialist installations |
| G10 | SR7 | G: concrete chainsaws, hydraulic jacks, pneumatic impact tools, diamond-core drills | 10 minutes | Vaults, strongrooms, specialist high-security |
| H20 | SR8 | H: the most powerful tools short of explosives and firearms | 20 minutes | Maximum resilience requirements |
LPS 1175 Issue 8 came into effect in 2019 and was the most substantial revision of the standard to date. It replaced the single SR1 to SR8 scale with a tool category letter (A to H) followed by a minimum delay in minutes (1, 3, 5, 10, 15 or 20). G10 is the Issue 8 classification commonly compared with the old SR7.
The letters shift between the two issues. Issue 7 used an enhanced Category D kit, written D+, for SR5, and Issue 8 turned that kit into Category E. Every tool category above it moved up a letter, so the Issue 7 tool set behind SR7, called Category F, corresponds to Issue 8 Category G. When comparing older documents with new ones, compare the rating, not just the letter.
SR7 compares with G10, not G15: G15 uses the same Category G tools but requires fifteen minutes of resistance, so it is a higher requirement than SR7. Issue 8 also allows ratings such as G5 and G20. Always check both the letter and the number on the certificate.
Specifier note: where a specification calls for LPS 1175 SR7, Issue 8 G10 is the current classification for that threat level. If the wording insists on Issue 7 specifically, confirm with the specifier whether a G10 product is acceptable.
At G10, the attacker has tools that cut concrete as easily as steel, so the building structure is exposed to the same attack as the certified product. A G10 rating is almost always part of a wider protective design, and several factors decide whether the certified delay is achieved in practice:
G10 is specified where the credible threat includes heavy professional equipment and the consequences of a breach are severe. Typical applications include:
A rating at this level should always come from a formal threat assessment. In government and critical infrastructure contexts, that assessment is typically informed by NPSA (National Protective Security Authority) guidance, and it will set the attacker profile, the response time and therefore the rating required for each layer.
Rare at this level: products certified to SR7 (G10) are rare. If a product or manufacturer claims G10 or SR7, verify the claim directly against LPCB Red Book Live before specifying.
G10 is the Issue 8 classification commonly compared with SR7: both describe an attack with heavy professional equipment held off for at least ten minutes. Because Issue 8 turned the old D+ tool kit into Category E, the Issue 7 tool set behind SR7, called Category F, corresponds to Issue 8 Category G. A product holds whichever rating is on its LPCB certificate.
SR7 compares with G10. G15 uses the same Category G tools but requires fifteen minutes of resistance instead of ten, so it is a higher requirement. Check both the letter and the number on the certificate.
The Category G tool set: everything in Categories A to F, including cordless and mains-powered saws and grinders and oxyacetylene cutting equipment, plus concrete chainsaws, hydraulic jacks, pneumatic impact tools, 2000W drills with diamond-core bits and petrol-driven disc grinders. Testers attack the locked product and must not create a 400 mm x 225 mm opening within ten minutes of working time.
Both require a ten-minute delay, but G10 adds heavy construction and demolition equipment to the F10 tool set. F10 is built around mains-powered saws and grinders and oxyacetylene cutting; G10 adds concrete chainsaws, hydraulic jacks, pneumatic impact tools and diamond-core drills, which can cut and force materials that F10 tools struggle with.
G10 is a specialist rating for vaults, strongrooms, cash and bullion centres, high-value secure stores and the most sensitive areas of government, defence and critical infrastructure sites. The requirement should come from a formal threat assessment, typically informed by NPSA guidance.
Ask for the LPCB certificate and check the product's current listing on Red Book Live. Confirm the issue of the standard, the full rating (letter and number), the certified sizes and configurations, and the locking systems covered. G10 products are rare, so a claim without an LPCB listing should not be relied on in a formal specification.
Issue 8 continues with longer delays at Category G, such as G15 and G20, and with Category H. H20, commonly compared with SR8, uses the most powerful tools short of explosives and firearms and requires a twenty-minute delay. Products at these levels are rare, so verify any claim directly against Red Book Live.
Premier Security Ballistic & Blast Ltd works with security consultants, architects and specifiers on high-threat projects across government, defence and critical infrastructure.
Contact our technical team to talk through your threat assessment and the protection it calls for.
Get in Touch with Our Team