- Call on : +44 (0)20 8559 8295
- Open Hours : Mon-Fri 08:00 - 17:30
Premier Security Ballistic & Blast Ltd
FB2 to FB7 rated assemblies with BR rated glazing, independently tested and available dual certified with blast, fire and LPS 1175.
Explore ballistic protection →EXV rated doors, windows, glazing and curtain walling engineered for vehicle borne and hand carried explosive threats.
Explore blast protection →30 to 120 minute EI and E rated door sets, including the UK's leading dual certified fire and security assemblies.
Explore fire protection →Certified intruder resistant doors, windows, glazing and perimeter systems with Secured by Design status.
Explore LPS 1175 ratings →LPS 1175 H20, the Issue 8 rating commonly compared with SR8, is the highest classification in the standard. It certifies that a complete product has resisted an attack with the most powerful tools available short of explosives and firearms for at least twenty minutes, double the ten-minute delay of E10, F10 and G10. It is a maximum resilience rating for the most critical assets in government, defence and national infrastructure. This guide explains what H20 means, how it differs from G10 and SR8, and how to specify and verify an H20 product.
LPS 1175 is the Loss Prevention Standard for intruder resistant building components, published by the Loss Prevention Certification Board (LPCB), part of BRE Global. Every Issue 8 rating has two parts: the letter sets the tools and the attack scenario, and the number sets the minimum delay in minutes the product must achieve. H is the highest tool category and 20 minutes is the longest delay, so H20 sits at the very top of the Issue 8 scale.
At H20, the test team attacks the locked product with Category H tools and must not create a 400 mm x 225 mm opening, the minimum size a person can climb through, within twenty minutes of working time. Any part of the assembly can be targeted, including frames, infill panels, locks, hinges and fixings.
Category H represents the maximum resilience scenario in LPS 1175. It builds on everything in Categories A to G, which already includes mains-powered saws and grinders, oxyacetylene cutting, concrete chainsaws, hydraulic jacks and diamond-core drills, and extends to the most powerful tools available short of explosives and firearms. The exact tool list is set out in the standard.
The step to H20 is about time as well as tools. Doubling the delay to twenty minutes against the most capable attack in the standard gives a response force significantly longer to arrive, which is why H20 is reserved for assets where the consequences of a breach are the most severe.
| Issue 8 | Issue 7 | Tool category | Minimum delay | Typical use |
|---|---|---|---|---|
| G10 | SR7 | G: concrete chainsaws, hydraulic jacks, pneumatic impact tools, diamond-core drills | 10 minutes | Vaults, strongrooms, specialist high-security |
| H10 | None | H: the most powerful tools short of explosives and firearms | 10 minutes | Category H threat with a shorter required delay |
| H20 | SR8 | H: the most powerful tools short of explosives and firearms | 20 minutes | Maximum resilience requirements |
LPS 1175 Issue 8 came into effect in 2019 and was the most substantial revision of the standard to date. It replaced the single SR1 to SR8 scale with a tool category letter (A to H) followed by a minimum delay in minutes (1, 3, 5, 10, 15 or 20). H20 is the Issue 8 classification commonly compared with the old SR8, the top of the Issue 7 scale.
The letters shift between the two issues. Issue 7 used an enhanced Category D kit, written D+, for SR5, and Issue 8 turned that kit into Category E. Every tool category above it moved up a letter, so the Issue 7 tool set behind SR8, called Category G, corresponds to Issue 8 Category H. When comparing older documents with new ones, compare the rating, not just the letter.
H10 is not H20: Issue 8 allows Category H tools to be tested to shorter delays, such as H10 and H15. An H10 product uses the same tools but only has to resist for ten minutes, half the delay of H20, and has no Issue 7 equivalent. Always check both the letter and the number on the certificate.
Specifier note: where a specification calls for LPS 1175 SR8, Issue 8 H20 is the current classification for that threat level. If the wording insists on Issue 7 specifically, confirm with the specifier whether an H20 product is acceptable.
A rating at the top of the standard only delivers its full value inside a protective design built to the same level. Several factors decide whether a twenty-minute delay is achieved in practice:
Explosives and firearms are outside LPS 1175: even H20 excludes explosive and firearm attack. Where those threats are credible, specify blast resistance and ballistic resistance separately, each tested under its own standard. See our Blast Resistance and Ballistic Resistance guides.
H20 is specified only where a formal threat assessment calls for maximum resilience against the most capable attack the standard recognises. Typical applications include:
In government and critical infrastructure contexts, the threat assessment is typically informed by NPSA (National Protective Security Authority) guidance. It will set the attacker profile, the response time and therefore the rating required for each layer.
Rare at this level: products certified to SR8 (H20) are rare. If a product or manufacturer claims H20 or SR8, verify the claim directly against LPCB Red Book Live before specifying.
H20 is the Issue 8 classification commonly compared with SR8: both sit at the top of their scales and require a delay of at least twenty minutes. Because Issue 8 turned the old D+ tool kit into Category E, the Issue 7 tool set behind SR8, called Category G, corresponds to Issue 8 Category H. A product holds whichever rating is on its LPCB certificate.
Yes. Category H is the highest tool category and twenty minutes is the longest delay in Issue 8, so H20 is the top classification in the standard, just as SR8 was the top of the Issue 7 scale.
Category H builds on everything in Categories A to G, including mains-powered saws and grinders, oxyacetylene cutting, concrete chainsaws, hydraulic jacks and diamond-core drills, and extends to the most powerful tools available short of explosives and firearms. Testers attack the locked product and must not create a 400 mm x 225 mm opening within twenty minutes of working time.
H20 raises both parts of the rating. It uses the higher Category H tool set rather than Category G, and it doubles the minimum delay from ten minutes to twenty.
No. Both use the Category H tool set, but an H10 product only has to resist for ten minutes, half the delay of H20. H10 has no Issue 7 equivalent, and it does not meet an SR8 or H20 specification.
No. LPS 1175 excludes explosive and firearm attack at every level, including H20. Where those threats are credible, blast resistance (for example to ISO 16933 or EN 13123 and EN 13124) and ballistic resistance (EN 1522 and EN 1523) must be specified and tested separately.
Ask for the LPCB certificate and check the product's current listing on Red Book Live. Confirm the issue of the standard, the full rating (letter and number), the certified sizes and configurations, and the locking systems covered. H20 products are rare, so a claim without an LPCB listing should not be relied on in a formal specification.
Premier Security Ballistic & Blast Ltd works with security consultants, architects and specifiers on high-threat projects across government, defence and critical infrastructure, including where forced entry, ballistic and blast threats overlap.
Contact our technical team to talk through your threat assessment and the protection it calls for.
Get in Touch with Our Team